ΕΞΑΕΡΙΣΤΗΡΕΣ ΟΡΟΦΗΣ ΑΝΤΙΠΥΡΙΚΟΥ ΤΥΠΟΥ TCDH-Exd-060-4
ΕΞΑΕΡΙΣΤΗΡΕΣ ΟΡΟΦΗΣ ΑΝΤΙΠΥΡΙΚΟΥ ΤΥΠΟΥ TCDH-Exd-060-4
SKU:
N/A
Categories: FRAME AXIAL FANS, AXIAL CYLINDRICAL VENTILATORS, VENTILATION-VENTILATION
Tags: Industrial Press, fans
Description
ΕΞΑΕΡΙΣΤΗΡΕΣ ΟΡΟΦΗΣ ΑΝΤΙΠΥΡΙΚΟΥ ΤΥΠΟΥ TCDH-Exd-060-4
- Μοτέρ 230V/400V – 50Hz, 4,6 the 8 poles.
- Protection IP55, Category F.
- Fireproof type according to ATEX Directive.
- Type Ex II2G EExd IIBT4.
- Impeller with rear tilt fins.
Special design for removal of dangerous and explosive gases
- Όλα τα μοντέλα διαθέτουν πλέγμα προστασίας.
- Θερμοκρασίες λειτουργίας έως +60℃.
- Με θερμικό προστασίας 155℃ ρυθμιζόμενο χειροκίνητα.
APPLICATIONS: For laboratory ventilation, shops, offices, houses etc.
| TYPE | TURNS
rpm |
POWER
kW |
CURRENT
A |
DELIVERY
m3/h |
Noise level
dB(A)
|
WEIGHT
kg |
| TCDH-Exd-060-4 | 1500 | 0,75 | 2,2 | 7.000 |
|
57 |
Product Catalog
TECHNICAL BROCHURE MANUAL
Related products
Axial Fans | CGT-CHGT series
IN-BOX VARIABLE VENDOR AXIAL FANS
CGT-CHGT SERIES
Open the brochure
Open the CHGT commercial brochure
- Axial fans within a square frame.
- Aluminum variable pitch impeller 3, 6 and 9 fins.
- Three-phase motor 400V, 50Hz.
- Motor protection IP55, Category F.
- Extremely robust all-aluminum construction.
- Suitable for special applications of high requirements, underground parking, shopping malls, public buildings.
- Type CHGT with endurance motor 400oC the first 2 hours and 200oC subsequently.
- Upon request with motor 2 gears, 2, 4, 6, the 8 poles or explosion-proof motors.
- Setting with INVERTER.
Axial Fans | HDT-HDB series
EXPLOSIVE EXPLOSIVE TYPES VENTILATORS
HDT-HDB SERIES
Open the brochure
- With motor 400V explosive type EEXDIIB T5 the EExdIIC T4.
- 1400rpm.
- Motor protection IP55.
- Category F.
- Impeller made of die-cast aluminum.
- With a dense strong protection grid.
- Models with motors are also available on request 6 and 8 poles.
- The models 315 and 355 are also available at 220V.
- Suitable for electronic automation roofs, batteries, transformers, engine rooms, chemical laboratories, explosive atmospheres.
- Setting with INVERTER.
Axial Fans | TBT series
HIGH PRESSURE CYLINDER CYLINDER VENTILATORS
TBT SERIES
Open the brochure
- Large manometric height.
- Suitable for ventilation of industrial and storage areas.
- Category F. Three-phase motor IP55.
- One pressure aluminum impeller.
- Ability to adjust speed.
Axial Fans | TCBBx2-TCBTx2 230V series
CYLINDRICAL CASON VENTILATORS WITH TWO OPPOSITE WINGS
TCBBx2-TCBTx2 230V SERIES
Open the brochure
- TCBB single phase 230V 50Hz.
- TCBT three-phase 400V 50Hz.
- Aluminum impeller with thin profile fins that achieve high performance.
- Suitable for extremely high pressures as the two impellers double the static pressure.
- With two motors (one for each impeller) ending in one terminal box.
- Category F for air temperature from -40°C to +170°C with thermal protection.
- The models 450 and 500 are regulated rheostatically.
Axial Ventilators | TGT-THGT 230V series
AXLE CYLINDRICAL VENTILATORS VEHICLE VARIABLE
TGT-THGT SERIES 230V
Open the brochure
EN_THGT
- Axial fans with variable inclination impeller made of aluminum.
- Three-phase motor 400V, 50Hz.
- Motor protection IP55, Category F.
- Extremely robust all-aluminum construction.
- Suitable for special applications of high requirements, underground parking, shopping malls, public buildings.
- Type THBIT with endurance motor 400°C the first 2 hours and 200°C subsequently.
- Upon request with motor 2 gears, 2, 4, 6, the 8 poles or explosion-proof motors.
- Guy LC has a wide body.
- Setting with INVERTER.
Axial Fans | TJFT / TJFU / TJHT series
AXIAL PROMOTION VENTILATORS
TJFT SERIES
1 SPEED, 2 ΠΟΛΩΝ
Open the brochure
- Cylindrical air ventilation fans - jet fans.
- For air transfer from -20 °C up to + 40 °C.
- Three-phase motor 400V one or two speeds.
- Motor protection IP55. Category F.
- Exterior terminal.
- Axial aluminum impeller.
- Type TJHT with endurance motor 400°C for 2 hours (F400-120).
- Case made of hot-dip galvanized steel.
- The air inlet and outlet cylinders are suitably soundproofed in the form of a sound trap.
- Suitable for fast air advance in closed or underground parking lots, tunnels, tunnel.
- Also suitable as fume hoods.
- ON REQUIREMENT: - With motor 2 gears 2/4 poles. - With 400 ° end motorC/2h, class F (TJHT). - With air direction blinds.
Axial Fans | TJFT / TJFU / TJHT series
AXIAL PROMOTION VENTILATORS
TJFT SERIES
2 SPEEDS, 2/4 ΠΟΛΩΝ
Open the brochure
- Cylindrical air ventilation fans - jet fans.
- For air transfer from -20 °C up to + 40 °C.
- Three-phase motor 400V one or two speeds.
- Motor protection IP55. Category F.
- Exterior terminal.
- Axial aluminum impeller.
- Type TJHT with endurance motor 400°C for 2 hours (F400-120).
- Case made of hot-dip galvanized steel.
- The air inlet and outlet cylinders are suitably soundproofed in the form of a sound trap.
- Suitable for fast air advance in closed or underground parking lots, tunnels, tunnel.
- Also suitable as fume hoods.
- ON REQUIREMENT: - With motor 2 gears 2/4 poles. - With 400 ° end motorC/2h, class F (TJHT). - With air direction blinds.