AIR CONDITIONER 9000 BTU MITSUBISHI heavy SERIES SRK-ZSP-W “SRK/SRC-25ZSP-W”

AIR CONDITIONER 9000 BTU MITSUBISHI heavy SERIES SRK-ZSP-W “SRK/SRC-25ZSP-W”

Drastic changes in design and engineering developments have brought about a huge improvement in energy efficiency and environmental protection.Dehumidification Function

High Power function

24hour programmable timer

Sleep timer

On-Off timer

Start Comfort

Microcomputer controlled defrosting

Self-diagnosis function

Automatic restart function

Small outdoor unit dimensions

Backup Switch

BTU/H

Manufacturers

Description

AIR CONDITIONER 9000 BTU MITSUBISHI heavy SERIES SRK-ZSP-W “SRK/SRC-25ZSP-W”

Indoor unit SRK25ZSP-W SRK35ZSP-W SRK45ZSP-W SRK50ZSP-W
Outdoor unit SRC25ZSP-W SRC35ZSP-W SRC45ZSP-W SRC50ZSP-W
Power supply Single phase, 220 – 240, 50Hz
Nominal cooling efficiency (Min.~Max.) kW 2.5(0.9~3.1) 3.2(0.9~3.7) 4.5(1.3~4.8) 5.0(1.3~5.2)
Nominal cooling efficiency (Min.~Max.) Btu/h 8.530(3.070~10.580) 10.920(3.070~12.620) 15.350(4.440~16.380) 17.060(4.440~17.740)
Rated heating efficiency (Min.~Max.) kW 2.8(1.0~4.1) 3.6(1.0~4.6) 5.0(1.2~5.8) 5.6(1.2~5.8)
Rated heating efficiency (Min.~Max.) Btu/h 9.550(3.410~13.990) 12.280(3.410~15.700) 17.060(4.090~19.790) 19.110(4.100~19.790)
Power consumption (Cooling heating) kW 0.710 / 0.690 0.910 / 0.930 1.350 / 1.360 1.740/1.660
SEER (middle zone) 6.8 703 6.3 6.2
Energy class-Cooling (middle zone) A++
SCOP (Middle/Warm zone) W/W 4.1/5.4 4.4/5.7 4.2/5.5 4.2/5.5
Energy class-Heating (Middle/Warm zone) A+/A+++
Max. operating current A 9 9 14,5 14,5
Indoor unit noise level (acoustic power) (Cooling heating) dB(A) 57 / 57 58 / 58 56 / 62 59 / 63
Noise level Outdoor unit (acoustic power) (Cooling heating) dB(A) 57 / 56 59 / 60 63 / 64 65 / 66
Indoor unit noise level (sound pressure) -Cooling (Hi/Me/Lo) dB(A) 45 / 34 / 23 45 / 36 / 23 44 / 39 / 24 46 / 39 / 24
Indoor unit noise level (sound pressure) Heating (Hi/Me/Lo) dB(A) 43 / 34 / 26 44 / 36 / 28 48 / 41 / 30 48 / 41 / 30
Noise level Outdoor unit (sound pressure)- Cooling heating dB(A) 47 / 45 48 / 48 51 / 51 52 / 52
Indoor unit air flow (Cooling (Hi/Me/Lo)) m3/min 10.0 / 7.3 / 4.2 9.5 / 6.8 / 4.2 9.0 / 7.2 / 3.8 9.9 / 7.2 / 3.8
Indoor unit air flow (Heating (Hi/Me/Lo)) m3/min 9.5 / 7.3 / 5.2 9.6 / 7.4 / 5.5 12.0 / 9.2 / 6.2 12.0 / 9.2/ 6.2
Outdoor unit air flow (Cooling heating) m3/min 23.7 / 19.7 22.8 / 22.0 35.6 / 33.4 37.7 / 35.6
External dimensions of indoor unit (HeightxWidthxDepth) mm 267 x 783 x 210
External dimensions of the outdoor unit (HeightxWidthxDepth) mm 540 x 645(+57) x 275 595 x 780(+62) x 290
Net weight (Internal/External) kg 7.0 / 26.5 7.0 / 28.5 7.5 / 36.0 7.5 / 36.0
Refrigerant (Type/GWP) R32 / 675
Refrigerant (Filling) kg/TCO2Eq 0.550 / 0.371 0.68 / 0.459 1.10 / 0.743 1.10 / 0.743
Pipe dimensions. Refrigerant (Liquid/Gas) ø mm 6.35(1/4″) / 9.52(3/8″) 6.35(1/4″) / 12.7(1/2″)
Refrigerant piping length (single track) m Max. 15 Max. 25
Height difference (Ext. h/d unit(vertically)) m Max. 10 / Max. 10 Max. 15 / Max. 15
Cable cross-sections (Contact-Delivery / Security) 4*1,5mm²-3*1,5mm² / 16A 4*1,5mm²-3*2,5mm² / 20A
Outdoor operating temperature range- Cooling ˚C -15~46
Outdoor operating temperature range- Heating ˚C -15~24
TRADE DIRECTORY

MHI-SR-SERIES-2022_revised