MITSUBISHI FDTC50VH SPLIT TYPE CASSETTE UNIT 4 DIRECTIONS

MITSUBISHI FDTC50VH SPLIT TYPE CASSETTE UNIT 4 DIRECTIONS

Request a Quote.

Add products to the shopping cart and send us the list to receive a quote.

 

Description

MITSUBISHI FDTC50VH SPLIT TYPE CASSETTE UNIT 4 DIRECTIONS

INDOOR UNIT FDTC50VH
OUTDOOR UNIT SRC50ZSX-W2
POWER SUPPLY SINGLE PHASE,220-240V,50Hz
RATED COOLING EFFICIENCY Nominative(Min.~Max.)
kW
Btu/h
5.0(1.1~5.6)
17.060(3.753~19.107)
NOMINAL HEATING EFFICIENCY Nominative(Min.~Max.)
kW
Btu/h
5.4(0.6~6.3)
18.425(2.047~21.496)
POWER CONSUMPTION Cooling heating kW 1.40/1.53
SEER Middle zone W/W 6.6
ENERGY CLASS Cooling-Mid zone A++
SCOP Middle/Warm zone W/W 4.3/-
ENERGY CLASS Heating-Medium/Warm zone A+/-
MAX. OPERATING CURRENT A 15
Noise level ( acoustic power)
Indoor
External
Cooling heating
Cooling heating
db(A)
59/59
63/62
Noise level (audible

pressure )

Indoor
Indoor
External
Cooling(Hi/Me/Lo/UIo)
Heating (Hi/Me/Lo/UIo)
Cooling heating
m3/minute
44/40/35/27
44/40/35/27
52/50
AIR FLOW
Indoor
Indoor
External
Cooling(Hi/Me/Lo/UIo)
Heating (Hi/Me/Lo/UIo)
Cooling heating
m3/minute
13/11/9/7
13/11/9/8
39/33
External dimensions
Indoor
External
HeightxWidthxDepth mm
Unit: 248x570x570 panel:10x620x620
640×800(+71)x290
NET WEIGHT Internal / External kg 16.5(Unit:14 Panel:2.5)/45.0
REFRIGERANT
Type/GWP
Filling
kg/TCO2ERq
R32/675
1.30/0.878
REFRIGERANT PIPING DIMENSIONS Liquid/Gas 0mm 6.35(1/4″)/12.7(1/2″)
REFRIGERANT PIPING LENGTH(length without padding ) m Mag.30 [15]
PEAK ALTITUDE DIFFERENCES Outdoor unit is higher/lower m Mag.20/ Mag.20
OUTDOOR OPERATING TEMPERATURE RANGE
Cooling
Heating
°CDB
-15~46
-20~24
Panel standard panel: TC -PSA-5AW-E(Cell),TC-PSAG-5AW-E(Grid)

Cold current protection panels:TC-PSAE-5AW-E(hive),TC-PSAGE-5AW-E(Grid)

MORE INFORMATION ABOUT THE PRODUCT:

  • Condensate pump The condensate pump allows greater installation flexibility, offering an excellent solution for applications with limited space.
  • Louver Adjustment System This function allows the user to adjust the upper and lower limit positions of the louver on each air outlet individually, providing full control of interior air flow.
  • Cold current protection setting Cold current protection provides comfortable airflow without any draft feeling. It either cools or heats a space, the control can be used to instantly suppress any hot or cold currents. This helps accurately determine how the airflow is directed as it exits the indoor unit.
  • Inverter technology Inverter control technology offers high efficiency and smooth operation from high to low speed. The electric voltage follows a smooth sinusoidal curve.
  • Energy saving function Since the performance is automatically controlled based on the outside temperature, energy can be saved without loss of comfort.
  • Motion sensor (optionally) The sensor detects human activity and adjusts the selected temperature according to the activity present in the space.
  • Home Leave mode This function ensures that when the room remains empty for long periods of time, the unit will maintain a moderate internal temperature, avoiding extremely high or low temperatures.
  • Auto Return selected temperature This feature allows the user to program a preferred set temperature that the unit will return to each time it is turned on.
  • Automatic operation This function automatically selects the required heating or cooling function based on the current room conditions.
  • High Power function Use the high power mode to quickly reach the optimal temperature level when you turn on the unit for the first time. This function will be activated for a max 15 minutes before returning to normal operation.
  • Vertical auto-rotate The blinds move continuously up and down and can be set to a fixed angle.
  • Automatic fan speed The unit's built-in microcomputer continuously monitors the room air temperature and automatically adjusts the air flow
  • Sleep timer The room temperature is automatically controlled during the period set in sleep mode, ensuring that the room temperature will be neither too cold nor too hot. Set a preset time between 30 and 240 minutes that your unit will run before shutting down.