AUX AHRV-5000/5 AUX AIR 5000 m3/h ERV 380V
AUX AHRV-5000/5 AUX AIR 5000 m3/h ERV 380V
Is widely used in high -rise buildings, hotels, office buildings, hospitals, shopping malls and banks, residential buildings and other places
Manufacturers |
---|
AUX AHRV-5000/5 AUX AIR 5000 m3/h ERV 380V
AUX's total heat exchanger is energy -saving equipment used to recover the air of air export air. Such a device does not require the main air conditioner to provide source of cold and heat, but heat exchanger through immediate air recovery in the air conditioner room.
Thus, is the standard energy -saving and environmentally friendly configuration, healthy buildings and an ideal partner of air conditioning. It consists mainly of a body of shell, Heat Core and Filters and other accessories. This device works by following the principle that through the material with heat and heat transmission in the core of the heat exchanger, Using exhaust air for pre -frozen and drying of fresh air in summer and warm -up and moisture fresh air in winter, so that the new fresh air load can be reduced significantly and thus save energy consumption and operating costs of the heating and cooling system.
Electricity consumption will also be reduced.
Such device is widely used in high -rise buildings, hotels, office buildings, hospitals, shopping malls and banks, residential buildings and other places
AUX's innovative centrifugal fan provides more air volume but lower noise, making the supply of air quieter and smoothly.
Related products
Axial Fans | KAF Series Single Phase
- 4-wing aluminum impeller (6-wing on the KAF-602).
- With motor 220V & 380V.
- 1400 rpm
- With thermal protection.
- Diameters from Φ250mm to Φ600mm.
- With protective grid.
Axial Fans | CGT-CHGT series
- Axial fans within a square frame.
- Aluminum variable pitch impeller 3, 6 and 9 fins.
- Three-phase motor 400V, 50Hz.
- Motor protection IP55, Category F.
- Extremely robust all-aluminum construction.
- Suitable for special applications of high requirements, underground parking, shopping malls, public buildings.
- Type CHGT with endurance motor 400oC the first 2 hours and 200oC subsequently.
- Upon request with motor 2 gears, 2, 4, 6, the 8 poles or explosion-proof motors.
- Setting with INVERTER.


Axial Fans | Compact 400V series
- TCFB with 230V motor.
- TCFT with 400V motor.
- TCF with impeller made of reinforced PVC.
- TCB with reinforced aluminum impeller.
- With high motor protection IP65.
- Category F for air temperatures from -40o C to +70o C.
- Suitable for industrial spaces, pigsties, poultry farms, greenhouses, dryers, warehouses etc..
- Set to 230V with dimmer REB-5000W and invert with REB-1R.
- Set to 400V with INVERTER.


Axial Fans | PBB-PBT 400V series
- PBB with 230V motor.
- PBT with 400V motor.
- With high motor protection IP65.
- Category F for air temperature -40°C to +70°C.
- With thermal protection.
- Reinforced impeller PVC.
- Designed to achieve high air supply.
- Suitable for commercial and industrial use.
- Set to 230V with REB-5000W and in 400V with INVERTER.

Axial Fans | TBT series
- Large manometric height.
- Suitable for ventilation of industrial and storage areas.
- Category F. Three-phase motor IP55.
- One pressure aluminum impeller.
- Ability to adjust speed.

Axial Fans | TJFT / TJFU / TJHT series
- Cylindrical air ventilation fans - jet fans.
- For air transfer from -20 °C up to + 40 °C.
- Three-phase motor 400V one or two speeds.
- Motor protection IP55. Category F.
- Exterior terminal.
- Axial aluminum impeller.
- Type TJHT with endurance motor 400°C for 2 hours (F400-120).
- Case made of hot-dip galvanized steel.
- The air inlet and outlet cylinders are suitably soundproofed in the form of a sound trap.
- Suitable for fast air advance in closed or underground parking lots, tunnels, tunnel.
- Also suitable as fume hoods.
- ON REQUIREMENT: - With motor 2 gears 2/4 poles. - With 400 ° end motorC/2h, class F (TJHT). - With air direction blinds.

Axial Fans | TJFT / TJFU / TJHT series
- Cylindrical air ventilation fans - jet fans.
- For air transfer from -20 °C up to + 40 °C.
- Three-phase motor 400V one or two speeds.
- Motor protection IP55. Category F.
- Exterior terminal.
- Axial aluminum impeller.
- Type TJHT with endurance motor 400°C for 2 hours (F400-120).
- Case made of hot-dip galvanized steel.
- The air inlet and outlet cylinders are suitably soundproofed in the form of a sound trap.
- Suitable for fast air advance in closed or underground parking lots, tunnels, tunnel.
- Also suitable as fume hoods.
- ON REQUIREMENT: - With motor 2 gears 2/4 poles. - With 400 ° end motorC/2h, class F (TJHT). - With air direction blinds.

Axial Fans | TTT series
- Axial cylindrical air duct fans.
- Indirect movement through belts and pulleys.
- Motor 400V with protection IP55, Category F.
- With thermal protection.
- With an easy adjustment wreath with the airway.
- Aluminum impeller coated with epoxy polyester paint.
- Easy maintenance, motor cleaning or replacement is done without disassembling the ventilator from the air duct.
- Suitable for exhaust corrosive and explosive gases, temperature up to 120°C.
- Ability to adjust speed with INVERTER.