TCL Outdoor unit Multi 32000 Btu/h FMA-3214HD/DVO

TCL Outdoor unit Multi 32000 Btu/h FMA-3214HD/DVO
  • Refrigerant R32 .R32 reduces environmental impact while improving energy efficiency thus reducing your bills.
BTU/H

Manufacturers

Category: Brand:
Description

TCL Outdoor unit Multi 32000 Btu/h FMA-3214HD/DVO

Refrigerant R32 .R32 reduces environmental impact while improving energy efficiency thus reducing your bills. Strong cooling to 53°. Ensure the appropriate temperature for cooling your space up to 53° outside temperature. DC Inverter compressor Ensures energy savings and reliability for air conditioning your space. Leak detector. In the event of a leak the unit will start the emergency program and stop its operation so that no further damage is caused to the unit. Strong heating at -20°. Keep the temperature inside your space regardless of the low temperatures outside. The compressor ensures continuous operation down to -20°.
TCL MODEL FMA-2713HD/DVO
TCL CONNECTIVITY 1 IN 4
Nominal cooling efficiency
Btu/h
w
32000(10600~35000)
9400(3100~10200)
Rated heating efficiency
Btu/h
w
32000(8700~35000)
9450(2550~10200)
phdesignc
Btu/h
W
32000
9300
SEER W/W 6.1
Energy class A ++
phdesignh(Average temp. zone) Btu/h 25000
W 7300
SCOP (Class) W/W 4.0
Energy class A +
Annual cooling energy consumption KWh 534
Average Annual Energy Consumption (Average Temp. zone ) KWh 2555
TCL Electrics
Electric Supply 220-240v~/50HZ
Operating voltage range V 165~265
Current in cooling mode A 14.1(1.8~17.0)
Current in cooling mode A 13.0(2.3~17.0)
Power supply cable Strands x Cross Section 3×2.5mm2
Characteristics of TCL cooling network
Refrigerant Type/Quantity/GWP/CO2 Equivalent R32/2200g/1,485t
Minimum network length (external to internal) m 3
Maximum network length (external to internal) m 25
Maximum total network length m 60
Total network length with prefill m 40
Additional refrigerant charge gr/m 15
Maximum altitude difference (external to higher internal) m 15
Minimum number of connected indoor units 2
Dimensions of TCL units
Net dimensions (MxYxB) mm 1005x910x400
Net weight kg 73
Indoor unit combination table
Standard combination of indoor units (Erp condition ) 09+09+09+09
An indoor unit /
Two indoor units 09+09,09+12,09+18,09+24

12+12,12+18,12+24,18+18,18+24

Three indoor units “09+09+09,09+09+12,09+09+18

09+09+24,09+12+12,09+12+18,

09+18+24,09+18+18,12+12+12,12+12+18

Four indoor units ’09+09+09+09,09+09+09+12,

09+09+09+18,09+09+12+12

Five indoor units

tcl tcl TCL Εξωτερικής μονάδας Multi 32000 Btu/h  FMA-3214HD/DVO lazy