Description

Split Type Heat Pumps 6 For ”AUX” ACHP-H06/4R3HA–I & ACHP-H06/4R3HA–O

Discover AUX's new range of AI – Therma heat pumps with the possibility of connecting to radiators, floor heating, fan coil units and simultaneous hot water production.

ACHP-H06 4R3HA
Performance 6kW
Indoor Unit Model ACHP-H06/4R3HA-I
Outdoor Unit Model ACHP-H06/4R3HA-O
Power supply
Indoor (V~,Hz,Ph) 220-240/1/50
External (V~,Hz,Ph) 220-240/1/50
Heating (7⁰C outside temperature)
Water outlet temperature 35⁰C
Performance (kW) 6.25
Consumption (kW) 1.25
COP 5.00
Water outlet temperature 35⁰C
Performance (kW) 6.40
Consumption (kW) 2.13
COP 3.00
Cooling (35⁰C outside temperature)
Water outlet temperature 18⁰C
Performance (kW) 6.60
Consumption (kW) 1.35
EER 4.90
Water outlet temperature 7⁰C
Performance (kW) 7.05
Consumption (kW) 2.35
EER 3.00
SCOP (middle zone)
Water Outlet 35⁰C 4.96
Water Outlet 55⁰C 3.53
Seasonal Energy Efficiency Class in Heating
Water Outlet 35⁰C A+++
Water Outlet 55⁰C A++
DC Inverter Compressor
Type Twin rotary GMCC
Crankcase (W) 25
Maximum Consumption
Indoor (kW) 3.09
External (kW) 4.14
MOP (Maximum Ampere Overcurrent Protection) (A) 18
Air supply (Outdoor unit) (m3/h) 2800
Piping Dimensions
Liquid (inch) 3/8″
Gas (inch) 5/8″
Distance In.-Ex, (min-max) (m) 2 / 30
Hydraulic Circuit
Hydraulic Connection (inch) R1″
Runoff Connection (mm) f25
Expansion Tank (L) 8
Auxiliary E-mail. Resistance (kW) 3
Water pump
Type Shimge
Manometric (m) 9
Maximum Supply 4.5m3/h
Weight
Interior Clean (kg) 38
Domestic Gross (kg) 44
Exterior Clean (kg) 51
External Gross (kg) 55
Dimensions (Μ×Β×Υ)
Internal Unit (mm) 420×270×790
Inner Packaging (mm) 515×1045×350
External Unit (mm) 900x350x700
Outer Packaging (mm) 1020x430x770
Coolant/Quantity/Maximum Prepaid Quantity Length R32 / 1.1kg / 15m
Adding Refrigerant 38gr/m more than 15m
Maximum distance In.-Ex. Altitude/Overall (max) 20/30
Temperature Adjustment Range
Cooling (°C) 5 ~ 25
Heating (°C) 25 ~ 65
DHW (container) (°C) 25 ~ 60
Outdoor Temperature Operating Range
Cooling (°C) -5 ~ 52
Heating (°C) -25 ~ 35
DHW (°C) -25 ~ 43
Noise level (Hi)
Indoor (dB(A)) 30
External (dB(A)) 38
Sound Power (Hi)
Indoor (dB(A)) 38
External (dB(A)) 58
Wiring
Internal supply (Cores x mm2) 3 x 4
External supply (Cores x mm2) 3 x 4
Communication (Armored) (Cores x mm2) 2 x 0,75
Notes
‡ Possibility of adjustment during installation as single-phase with auxiliary electric resistance 3kW.
According to EU standards and legislation: EN14511; EN14825; EN50564; EN12102; (EU) No 811:2013; (EU) No 813:2013; OJ 2014/C 207/02:2014.