Split Type Heat Pumps 12 Kw ”TO THE”ACHP-H12/5R3HA – I & ACHP-H12/5R3HA – 0
| Manufacturers | |
|---|---|
| kw |
Categories: heat pumps, DIVIDED, air conditioning
Brand: TO THE
Description
Split Type Heat Pumps 12 Kw ”AUX”ACHP-H12/5R3HA – I & ACHP-H12/5R3HA – 0
Discover AUX's new range of AI – Therma heat pumps with the possibility of connecting to radiators, floor heating, fan coil units and simultaneous hot water production.
| ACHP-H12 5R3HA | |
|---|---|
| Performance | 12kW |
| Indoor Unit Model | ACHP-H12/5R3HA-I |
| Outdoor Unit Model | ACHP-H12/5R3HA-O |
| Power supply | |
| Indoor (V~,Hz,Ph) | 380-415/3/50 ‡ |
| External (V~,Hz,Ph) | 220-240/1/50 |
| Heating (7⁰C outside temperature) | |
| Water outlet temperature 35⁰C | |
| Performance (kW) | 12.20 |
| Consumption (kW) | 2.44 |
| COP | 4.96 |
| Water outlet temperature 35⁰C | |
| Performance (kW) | 12.00 |
| Consumption (kW) | 3.86 |
| COP | 3.11 |
| Cooling (35⁰C outside temperature) | |
| Water outlet temperature 18⁰C | |
| Performance (kW) | 12.00 |
| Consumption (kW) | 3.00 |
| EER | 4.00 |
| Water outlet temperature 7⁰C | |
| Performance (kW) | 11.70 |
| Consumption (kW) | 4.25 |
| EER | 2.75 |
| SCOP (middle zone) | |
| Water Outlet 35⁰C | 4.82 |
| Water Outlet 55⁰C | 3.46 |
| Seasonal Energy Efficiency Class in Heating | |
| Water Outlet 35⁰C | A+++ |
| Water Outlet 55⁰C | A++ |
| DC Inverter Compressor | |
| Type | Twin rotary Panasonic |
| Crankcase (W) | 25 |
| Maximum Consumption | |
| Indoor (kW) | 9.09 |
| External (kW) | 9.2 |
| MOP (Maximum Ampere Overcurrent Protection) (A) | 14 |
| Air supply (Outdoor unit) (m3/h) | 4650 |
| Piping Dimensions | |
| Liquid (inch) | 3/8″ |
| Gas (inch) | 5/8″ |
| Distance In.-Ex, (min-max) (m) | 2 / 30 |
| Hydraulic Circuit | |
| Hydraulic Connection (inch) | R1″ |
| Runoff Connection (mm) | f25 |
| Expansion Tank (L) | 8 |
| Auxiliary E-mail. Resistance (kW) | 9 ‡ |
| Water pump | |
| Type | Shimge |
| Manometric (m) | 9 |
| Maximum Supply | 4.5m3/h |
| Weight | |
| Interior Clean (kg) | 39 |
| Domestic Gross (kg) | 45 |
| Exterior Clean (kg) | 100 |
| External Gross (kg) | 105 |
| Dimensions (Μ×Β×Υ) | |
| Internal Unit (mm) | 420×270×790 |
| Inner Packaging (mm) | 515×1045×350 |
| External Unit (mm) | 1060x480x870 |
| Outer Packaging (mm) | 1100x545x980 |
| Coolant/Quantity/Maximum Prepaid Quantity Length | R32 / 1,84kg / 15m |
| Adding Refrigerant | 38gr/m more than 15m |
| Maximum distance In.-Ex. Altitude/Overall (max) | 20/30 |
| Temperature Adjustment Range | |
| Cooling (°C) | 5 ~ 25 |
| Heating (°C) | 25 ~ 65 |
| DHW (container) (°C) | 25 ~ 60 |
| Outdoor Temperature Operating Range | |
| Cooling (°C) | -5 ~ 52 |
| Heating (°C) | -25 ~ 35 |
| DHW (°C) | -25 ~ 43 |
| Noise level (Hi) | |
| Indoor (dB(A)) | 31 |
| External (dB(A)) | 49 |
| Sound Power (Hi) | |
| Indoor (dB(A)) | 43 |
| External (dB(A)) | 64 |
| Wiring | |
| Internal supply (Cores x mm2) | 5 x 4 |
| External supply (Cores x mm2) | 3 x 4 |
| Communication (Armored) (Cores x mm2) | 2 x 0,75 |
| Notes | |
| ‡ Possibility of adjustment during installation as single-phase with auxiliary electric resistance 3kW. | |
| According to EU standards and legislation: EN14511; EN14825; EN50564; EN12102; (EU) No 811:2013; (EU) No 813:2013; OJ 2014/C 207/02:2014. |
TECHNICAL PRODUCT SHEET
ENERGY LABEL-CE