INSULATED COPPER COOLANT PIPE 3/8 ” TALOS ACR ECUTHERM” ROLL 30 METERS
INSULATED COPPER COOLANT PIPE 3/8 ” TALOS ACR ECUTHERM” ROLL 30 METERS
Manufacturers |
---|
0
People watching this product now!
SKU:
17.01.00002
Categories: INSULATED COPPER PIPE, COPPER PIPES-COPPER FITTINGS-BRASS FITTINGS
Tags: cooper pipe, preinsulated copper pipe, TALOS ACR, jacketed pipe, insulated pipe, pre-insulated copper pipe, pipe with insulation, copper pipes, copper pipe, χαλκορ, copper, copper pipes, cooling copper, copper cooling pipe
Description
INSULATED COPPER COOLANT PIPE 3/8 ” TALOS ACR ECUTHERM” ΡΟΛΛΟ 30 METERS
TALOSⓇ ACR ECUTHERM™
Cooling, Air conditioning
TALOS® ACR ECUTHERM™ Factory Insulated Copper Tubing, it is a product of advanced technology, of high added value and are significantly superior in efficiency compared to traditional ways of insulation.
Copper pipe construction material
Copper deoxidized with phosphorus (DHP-Cu) with minimal copper content 99,9% and P = 0,015% – 0,040%
Standards
COOLING PIPES: IN 12735-1
Quality signals
COOLING PIPES: AENOR, MOT, GL, VIK
Mechanical Characteristics
Product status | Notation according to EN 12735-1 | Minimum breaking load Rm (MPa) | Minimum elongation, A% |
---|---|---|---|
Soft | R-220 | 220 | 40 |
Insulation Technical Characteristics
PEF MATERIAL | PE-X/PE |
INSULATION THICKNESS | 9mm |
DENSITY VS, FROM 53420, ASTM D1667 | 30-33 kg/m3 |
COEFFICIENT OF THERMAL CONDUCTIVITY (l) KATA ASTM C 335 | 0,039W/m.K |
COEFFICIENT OF PERMEABILITY RESISTANCE TO HYDRATES-WATER (m) KATA DIN 52615 | > 9.000 |
OPERATING TEMPERATURE | -800C to 1100C (up to 800C for PE material) |
FIRE RESISTANCE | DIN 4102-B2, NF P 92 501-M1, CL1, YOUR ONE 13501 – 1 Class E & B |
CHEMICAL RESISTANCE ACCORDING TO ASTM 543-56 T | Very good |
SOUND INSULATION ACCORDING TO DIN 4109:300-2500 Ηz | ~60% |
DIMENSIONAL STABILITY ACCORDING TO ISO 2796 FOR TEMPERATURES UP TO 1000C | <5% |
Table values are stated as found under standard laboratory conditions and are subject to change without prior notice.
Standard Dimensions TALOS ACR ECUTHERM™ EN 12735-1
OUTSIDE DIAMETER OF COPPER PIPE INCH | EXTERNAL DIAMETER COPPER PIPE MM | COPPER WALL THICKNESS MM | TOTAL OUTSIDE DIAMETER WITH INSULATION 9 MM |
---|---|---|---|
3/16 | 4,76 | 0,80 | 22,76 |
1/4 | 6,35 | 0,80 | 24,35 |
5/16 | 7,94 | 0,80 | 25,94 |
3/8 | 9,52 | 0,80 | 27,52 |
1/2 | 12,70 | 0,80 | 30,70 |
5/8 | 15,87 | 1,00 | 33,87 |
3/4 | 19,05 | 1,00 | 37,05 |
7/8 | 22,23 | 1,00 | 40,23 |
TECHNICAL PRODUCT SHEET