MODEL TECHNICAL CHARACTERISTICS:DAI-ICHI AIR CONDITIONER
Dai-Ichi | |||
Model Indoor Unit | DHT22-24IVi | ||
Model Outdoor Unit | DHT22-24IVo | ||
Cooling Performance | W | 6810 | |
Cooling Performance | BTU | 23236 | |
Range Cooling Performance | W | 1830~7800 | |
Range Cooling Performance | BTU | 6.244 ~ 26.614 | |
Heating Performance | W | 6870 | |
Heating Performance | BTU | 23,440 | |
Range Heating Efficiency | W | 1850~7900 | |
Range Heating Efficiency | BTU | 6.312 – 26.955 | |
Pdesignc | kW | 6.8 | |
SEER | W/W | 6.1 | |
Cooling Energy Class | A++ | ||
Middle Belt Pdesignh | kW | 4.8 | |
Middle Zone SCOP | W/W | 4.0 | |
Middle Zone Heating Energy Class | A+ | ||
Pdesignh Warm Zone | kW | 5.6 | |
Hot Zone SCOP | W/W | 5.1 | |
Warm Zone Heating Energy Class | A +++ | ||
Annual Consumption | Cooling | kwh/a | 390 |
Heating Middle Zone | kwh/a | 1680 | |
Heating Warm Zone | kwh/a | 1537 | |
Dehumidification | Lt/h | 1.8 | |
Indoor Unit Sound Power (Turbo/H/M/L/Mute) | dB(A) | 54/51/48/44/40 | |
External Unit Sound Power (Hi) | dB(A) | 67 | |
Indoor Unit Noise Level (Turbo/H/M/L/Mute) | dB(A) | 44/41/38/34/30 | |
Outdoor Unit Noise Level (Hi) | dB(A) | 57 | |
Current Voltage/Frequency/Phase | 220-240V~/50Hz/1P | ||
Coolant Liquid | R32 | ||
Amount of coolant | kg | 1.14 | |
GWP | 675 | ||
CO2 equivalent | 0.770 | ||
Air supply (Turbo/H/M/L/Mute) | m3/h | 980/925/770/655/540 | |
Cooling Piping mm (inch) | Gas | 12.7 (1/2”) | |
Liquid | 6.35 (1/4”) | ||
Maximum Length | m | 25 | |
Max. Altitude Difference | m | 10 | |
Operating Limits | ℃ | 16-31 | |
Ambient temperature range | External | ℃ | Cooling:-15-53/Heating:-20-30 |
Indoor | ℃ | Cooling:17-32/Heating:0-30 | |
Product Dimensions (W x H x D)mm | Indoor | mm | 1010×315×220 |
External | mm | 920×699×380 | |
Net weight | Indoor | kg | 13 |
External | kg | 40 | |
Package dimensions (W x H x D)mm | Indoor | mm | 1096×390×297 |
External | 960x732x400 | ||
Gross weight | Indoor | kg | 16 |
External | kg | 43 | |
INVERTER FUNCTION | YES | ||
WI-FI READY | YES | ||
FILTERS | High Density Pre Filter | ||
3 in 1 | Ionization / Vitamin C / Catechin | ||
3 in 1 | Photocatalyst / Activated Carbon / Electrostatic | ||
Harmonized Standards: EN14511:2007, EN12102 | |||
HEATING POTENTIAL OF THE PLANET (GWP) 675 |
ADDITIONAL FUNCTIONS
ECO R32 COOLANT
It is completely environmentally friendly, it is easily recycled and achieves higher levels of performance, while contributing to longer product life.
WI-FI (READY)
Use technology to create the ideal conditions in your space from a distance !!! Choose the desired function whenever you want and from wherever you are and activate your air conditioner easily via your mobile phone or tablet!!!!
ECO/ENERGY SAVING FUNCTION
The air conditioner automatically adjusts the temperature based on the factory setting so as to achieve the maximum possible energy savings
8°C HEATING MODE
In case someone is away for a long time from home during the winter, the 8oC function ensures low consumption and a constant temperature of 8oC in the room so that it does not freeze
“ANTI COLD AIR” INTELLIGENT PREHEAT FUNCTION
With the smart preheating function, the air conditioner starts working in heating with a short delay from 1 – 5 minutes to heat up the copper pipe first so that cold air does not come out of the air conditioner. This prevents cold air from entering when the air conditioner starts up, with the result that conditions of discomfort are not created for the user
SMART DEFROST FUNCTION
The traditional defrost mode works based on a factory programmed start time. Thus, the defrost function can be activated even when the air conditioner does not need it. With the intelligent defrost function, the air conditioner only defrosts when it really needs it, resulting in a reduction in energy consumption and a more comfortable indoor temperature environment
“TURBO” FUNCTION
The air conditioner operates at a high frequency when starting the TURBO function and thus achieves very fast cooling or heating of the room
“AUTORESTART” FUNCTION
In the event of a power outage, the air conditioner remembers the mode of operation before the interruption. When the power is restored, the air conditioner automatically starts working in the same mode as before the interruption
“I-FEEL” FUNCTION
Second temperature sensor on the remote control for even more accurate recording of the actual room temperature
DRY FUNCTION
Select this function to reduce the humidity level of the room
REMOTE CONTROL LOCK FUNCTION “LOCK”.
By locking the functions of the air conditioner through the remote control, you ensure that it cannot be used accidentally by children or a pet
“DISPLAY” FUNCTION
Option to show or hide the function lights on the indoor unit
SELF-DIAGNOSTIC FAULT SYSTEM
Fault finding is very easy through the microcomputer self-diagnostic system
MEMORY OF THE DESIRED POSITION OF THE SHUTTER
Conventional air conditioners cannot memorize the last position of the louver after shutting down their operation. On restarting it, louver position is adjusted based on factory specifications. The air conditioners that have the intelligent memorization of the louvre position, they allow the user to maintain the position he has chosen as ideal, when restarting the air conditioner
AUTOMATIC HORIZONTAL SHUTTER MOVEMENT
Adjust the desired wind position (give or take) through the remote control
AUTOMATIC VERTICAL SHUTTER MOVEMENT
Adjust the desired wind position (right left) through the remote control
“SLEEP” FUNCTION
Set your air conditioner to SLEEP mode for comfortable conditions during sleep
TIMER FUNCTION
Use the TIMER button to set the time you want the air conditioner to start or stop automatically
“I SET” FUNCTION
To remember favorite function settings
“MUTE” FUNCTION
For ultra-quiet operation
SELF CLEAN FUNCTION 56OC.
The Self-Cleaning function ensures the removal of dirt, dust and moisture from the internal element. Prevents the formation of mold and fights germs and viruses as well as unpleasant odors. A clean interior means a healthy atmosphere, better performance and energy saving Self-cleaning is carried out as follows: 1the stage: Cooling works on high and freezes the element for 16 minutes. 2the stage: The air conditioner operates in Defrost mode for 15 minutes. 3the stage: The air conditioner works on Heating at a very high temperature for 4 minutes where sterilization of the inner element takes place.