Air conditioner 12000 BTU Toyotomi series ERAI MIDNIGHT BLUE CTN/CTG-235BRM

The new ErAI series of air conditioners with integrated artificial intelligence technology offers a personalized experience by adapting its operation to your own needs.

It continuously collects information via microchip and effectively and flexibly deals with differences in ambient temperature, of the size of the room and the thermal load offering you absolute comfort and maximum energy savings.

BTU/H

Manufacturers

Description
MODEL TECHNICAL CHARACTERISTICS:CTN/CTG-235BRM
MIDNIGHT BLUE MODEL CTN/CTG-235BRM
PLANNING LOAD (Pdesign)
COOLING DESIGN LOAD (Pdesignc) kW 3,5
MID-ZONE HEATING DESIGN LOAD (Pdesignh) kW 3,2
WARM ZONE HEATING DESIGN LOAD (Pdesignh) kW 3,2
REFRIGERATION / THERMAL EFFICIENCY
COOLING*
PERFORMANCE
Btu/h 11976
kW 3,51
PERFORMANCE RANGE
Btu/h 3.071 – 15.013
kW 0,90 – 4,40
HEATING*
PERFORMANCE
Btu/h 13000
kW 3,81
PERFORMANCE RANGE
Btu/h 3.071 – 16.036
kW 0,90 – 4,70
SEASONAL PERFORMANCE DEGREE
COOLING (Pdesignc)
SEER 7,2
Cooling Energy Class A++
HEATING (Pdesignh)
Medieval SCOP 4,1
Medium Season Heating Energy Class A+
Warmer Season SCOP 5,2
Warmer Season Heating Energy Class A+++
ELECTRICAL CHARACTERISTICS
CURRENT VOLTAGE/FREQUENCY Ph-V-Hz 1-220~240V-50
COOLING (Pdesignc) ANNUAL CONSUMPTION (QCE) kWh/a 170
HEATING (Pdesignh)
ANNUAL CONSUMPTION OF AVERAGE SEASON (WHEE) kWh/a 1093
ANNUAL HOT SEASON CONSUMPTION (WHEE) kWh/a 862
PERFORMANCES
DEHYDRATION L/h 1.40
INDOOR UNIT AIR SUPPLY (SHi/Hi/Mhi/M/MLo/Lo/SLo) m3/h 680/620/560/490/450/420/390
INDOOR UNIT SOUND POWER (SHi/Hi/Mhi/M/MLo/Lo/SLo) dB(A) 60/55/53/50/47/44/42
NOISE LEVEL OF INDOOR UNIT (SHi/Hi/Mhi/M/MLo/Lo/SLo) dB(A) 41/38/36/33/30/27/25
OUTDOOR UNIT SOUND POWER (Hi) dB(A) 63
OUTDOOR UNIT NOISE LEVEL (Hi) dB(A) 52
DIMENSIONS AND WEIGHT
INDOOR UNIT
dimensions (P*Y*B) mm 837×293×200
PACKAGE DIMENSIONS (P*Y*B) mm 909×276×366
Net/Gross WEIGHT Kg 9,5/11,5
OUTDOOR UNIT
dimensions (P*Y*B) mm 732×555×330
PACKAGE DIMENSIONS (P*Y*B) mm 791×590×373
Net/Gross WEIGHT Kg 25,5/28
OUTDOOR UNIT ENCLOSURE Metallic
PIPE SIZE
COOLING PIPES
Liquid Diameter mm (inch) 6.35 (1/4”)
Gas Diameter mm (inch) 9,53 (3/8”)
Maximum Length m 15
Max. Altitude Difference m 10
General characteristics
ALL DC INVERTER OPERATION YES
Operating Limits oC
Cooling -15~50
Heating -25~30
COOLANT R32
AMOUNT OF COOLANT kg 0,57
CO2 EQUIVELANT Tons 0,38475
ARTIFICIAL INTELLIGENCE “AI” YES
UV AIR STERILIZATION YES
PLASMA IONIZER YES
WI-FI PRE-INSTALLED
FILTERS
High Density Pre Filter
x HEPA 3PLUS (HEPA/Silver Ion/Biology sterillization)
x Photocatlytic
Harmonized Standards: EN14511:2007, EN12102*
HEATING POTENTIAL OF THE PLANET (GWP) 675
AI "ARTIFICIAL INTELLIGENCE"

Through Artificial Intelligence TOYOTOMI Erai intelligent air conditioner adjusts its operation according to environmental changes, the needs and habits of the user achieving high yields, energy saving and maximum comfort in the space

ALL DC INVERTER

For more effective operational control, For better performance and lower energy consumption, For a faster response in reaching the requested Set-Points, For even distribution & air diffusion due to the inverter controlled internal fan, For lower noise levels of both indoor and outdoor units

CONTROLLED PERFORMANCE LIMIT “P” FUNCTION

The air conditioner intelligently reduces its efficiency by 25% or also 50% to cope with any possible unstable power supply and to save maximum energy

mode 8OC IN THE HEATING

In case someone is away for a long time from home during the winter, the 8oC function ensures low consumption and constant temperature 8oC in the room so it doesn't freeze.

ECO R32 COOLANT

TOYOTOMI adheres to the ECO Design directive for environmental and energy saving issues, uses the unique R32 refrigerant in all home air conditioning ranges. It is completely environmentally friendly, it is easily recycled and achieves higher levels of performance, while contributing to longer product life.

ENERGY SAVING FUNCTION
The air conditioner automatically adjusts the temperature based on the factory setting so as to achieve the maximum possible energy savings.
DOOR CARD CONTROL FUNCTION

Can be connected to a door or window trap. Ideal function for hotel solutions.

HOTEL MENU FUNCTION

With special optional controller, it is possible to adjust the range of the desired temperature for even greater energy savings. Ideal function for hotel solutions.

OPERATION I SENSE
There are in the air conditioning unit 2 temperature sensors. One is located on the indoor unit and determines the default temperature and the second is located on the remote control and offers the possibility of alternative temperature setting. The room temperature varies according to height, so by selecting the smart I Feel function the temperature you have chosen will be maintained based on the position of the remote control, i.e. your own location and not based on the temperature, prevailing on the indoor unit.
WI-FI OPERATION (PRE-INSTALLED)
Use technology to create the ideal conditions in your space from a distance !!! Choose the desired function whenever you want and from wherever you are and activate your air conditioner easily via your mobile phone or tablet!!
SMART PREHEAT FUNCTION “SP”

With the smart preheating function, the air conditioner starts working in heating with a short delay from 1 – 5 minutes to heat up the copper pipe first so that cold air does not come out of the air conditioner. This prevents cold air from entering when the air conditioner starts up, with the result that conditions of discomfort are not created for the user.

SMART AUTO LED PHOTO SENSITIVITY

The built-in photosensitive sensor automatically senses ambient light changes around the unit and adjusts the brightness of the indicators on the indoor unit so you can enjoy a carefree and restful sleep!

SMART DEFROST FUNCTION

The traditional defrost mode works based on a factory programmed start time. Thus, the defrost function can be activated even when the air conditioner does not need it. With the intelligent defrost function, the air conditioner only defrosts when it really needs it, resulting in a reduction in energy consumption and a more comfortable indoor temperature environment.

SMOOTH START FUNCTION

For extra protection of the board at home, in case e.g. there are many air conditioners. When a conventional air conditioner starts its operation, a high current is required during start-up. If there are a lot of air conditioners, this can cause a problem with the house panel. With the Soft Start function, the air conditioner is activated at low current during start-up, resulting in extra protection of the panel at home.

TURBO FUNCTION

The air conditioner operates at a high frequency when starting the TURBO function and thus achieves very fast cooling or heating of the room.

AUTORESTART FUNCTION
In the event of a power outage, the air conditioner remembers the mode of operation before the interruption. When the power is restored, the air conditioner automatically starts working in the same mode as before the interruption.
DRY FUNCTION
Select this function to reduce the humidity level of the room.
REMOTE CONTROL LOCK FUNCTION “LOCK”
By locking the functions of the air conditioner through the remote control, you ensure that it cannot be used accidentally by children or a pet.
LIGHT / LIGHT OUT FUNCTION

Option to show or hide the function lights on the indoor unit.

SELF-DIAGNOSTIC FAULT SYSTEM
Fault finding is very easy through the microcomputer self-diagnostic system.
AUTOMATIC HORIZONTAL SHUTTER MOVEMENT
Adjust the desired wind position (give or take) through the remote control.
AUTOMATIC VERTICAL SHUTTER MOVEMENT
Adjust the desired wind position (right left) through the remote control.
“SLEEP” FUNCTION
Set your air conditioner to SLEEP mode for comfortable conditions during sleep.
TIMER FUNCTION
Use the TIMER button to set the time you want the air conditioner to start or stop automatically.
OUTDOOR UNIT ELECTRICAL RESISTANCE

For protection against extreme low temperatures and trouble-free operation even at -25o C

ROOM TEMPERATURE OR HUMIDITY INDICATION

For easy control of the conditions in our area

MEMORY OF THE DESIRED POSITION OF THE SHUTTER

Conventional air conditioners cannot memorize the last position of the louver after shutting down their operation. On restarting it, louver position is adjusted based on factory specifications. The air conditioners that have the intelligent memorization of the louvre position, they allow the user to maintain the position he has chosen as ideal, when restarting the air conditioner.

POSSIBILITY OF CONNECTION THROUGH A WIRE CONTROLLER
QUIET MODE

Select the Quiet mode via the remote control, for silent operation

VOICE CONTROL FUNCTION

Control your air conditioner using just your voice! Talk to it and it will respond to your commands via Voice assistants!

TRADE DIRECTORY

ERAI_Entypo_2022_2