AIR DUCT AIR CONDITIONER 24000 BTU TCL TCC-24D2HRH/DV
MODEL | TCC-24D2HRH/DV | ||
---|---|---|---|
Indoor unit | TCC-24D2HRH/DVI | ||
Outdoor unit | TCC-24HRH/DVO | ||
Nominal cooling efficiency | Btu/h | 24000(7500~27000) | |
W | 7040(2200~7920) | ||
Nominal heating efficiency | Btu/h | 26000(7900~28500) | |
W | 7620(2320~8350) | ||
Pdesignc | W | 7000 | |
SEER | W/W | 6.1 | |
Energy Class Cooling | A++ | ||
Pdesignh (Middle zone) | W | 5600 | |
SCOP (Middle zone) | W/W | 4.0 | |
Heating energy class (Middle zone) | A+ | ||
Annual energy consumption (Middle zone) | Cooling | kwh/a | 402 |
Heating | kwh/a | 1960 | |
Operating temperature range | °C | 16-31 | |
Ambient temperature range | External | °C | Cooling:-15~53 / Heating:-20~30 |
Indoor | °C | Cooling:17~32/Heating:0~30 | |
AIR SUPPLY AND NOISE LEVEL | |||
Indoor unit air supply (Cooling heating) | m3/h | 1000/1250 | |
External static pressure of indoor unit (Range) | Pa | 0-80 | |
Sound power level (S/H/M/L/Silent) | Indoor | dB(A) | 48/46/42/36/34 |
Sound power level (Typical conditions) | External | dB(A) | 55 |
ELECTRICAL COMPONENTS | |||
Electrical supply/Connection | Indoor:220-240V~/50Hz/1P External:220-240V~/50Hz/1P |
||
Power Supply Voltage Range | V | Indoor:176~265 External: 176~265 |
|
Maximum Current | A | 13.5 | |
Communication cable | 3x 0.75mm² | ||
Power supply cable | Strands x Cross Section | Indoor:3×1.0mm² External:3×2.5mm² |
|
PIPING CHARACTERISTICS | |||
Cross section | Gas | Inches | 1/2″ |
Liquid | Inches | 1/4″ | |
Maximum length | m | 50 | |
Maximum altitude difference | m | 25 | |
Refrigerant Type/Quantity/GWP/CO2 Equivalent | R32/1.25kg/675/0.844tons | ||
DIMENSIONS OF UNITS | |||
Net dimensions (W x H x D) |
Indoor | mm | 920×270×570 |
External | mm | 845×330×694 | |
Panel | mm | / | |
Net weight | Indoor | kg | 27 |
External | kg | 39 | |
Panel | kg | / |